Specifications:
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
Function | Range | Resolution | Accuracy | |
AC volts (40 Hz to 500Hz)1 |
4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0% + 3 | |
DC volts | 4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5% + 3 | |
AC millivolts | 400.0 mV | 0.1 mV | 3.0% + 3 | |
DC millivolts | 400.0 mV | 0.1 mV | 1.0% + 10 | |
Diode test2 | 2.000 V | 0.001 V | 10% | |
Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 |
|
Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 |
|
Frequency1 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1% + 3 | |
Duty Cycle1 | 1% to 99% | 0.1% | 1% typical 4 | |
AC current μA (40 Hz to 400 Hz) |
400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5% + 3 | |
AC current mA (40 Hz to 400 Hz) |
40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 | |
AC current A (40 Hz to 400 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 | |
DC current μA | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5% + 3 | |
DC current mA | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 | |
DC current A | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 | |
Temperature | 50 °C- 400 °C 0 °C- 50 °C -55 °C- 0 °C |
0.1C | 2% ±1 °C ±2 °C 9% ±2 °C |
|
Backlight | – | – | Yes | |
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%. |
Function | Overload protection | Input impedance (Nominal) | Common mode rejection ratio | Normal mode rejection ratio |
AC volts | 1000 V 1 | >10 MΩ <100 pF | >60 dB at dc, 50 Hz or 60 Hz |
– |
AC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | – |
DC volts | 1000 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
DC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | – |
1 106 V Hz Max |
General specifications | |
Maximum voltage between any terminal and earth ground | 1000 V |
Display (LCD) | 4000 counts, updates 3/sec |
Battery type | 2 AA, NEDA 15A, IEC LR6 |
Battery life | 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.) |
Temperature | |
Operating | 0 °C to 40 °C |
Storage | -30 °C to 60 °C |
Relative humidity | |
Operating humidity | Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C ≤75% RH at 30 °C to 40 °C |
40 MΩ range ≤80% RH at 10 °C to 30 °C ≤70% RH at 30 °C to 40 °C |
|
Altitude | |
Operating | 2000 m |
Storage | 12,000 m |
Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Fuse protection for current inputs | 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only. |
Size (H x W x L) | 183 x 91 x 49.5 mm |
Weight | 455 g |
IP rating | IP 40 |
Safety | IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2 |
Electromagnetic environment | IEC 61326-1: Portable |
Electromagnetic compatibility | Applies to use in Korea only |
Class A equipment (industrial broadcasting and communication equipment)1 1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. |
Request Stock
Recently viewed products
You might also be interested in...
Customers who bought this also bought...
General Questions
-
What is the latest price of the FLUKE 17B+ Digital Multimeter in Bangladesh?
The latest price of FLUKE 17B+ Digital Multimeter in Bangladesh is Special Price BDT 16,999.00 Regular Price BDT 20,044.00 . You can buy the FLUKE 17B+ Digital Multimeter at the best price on BDTronics.com or contact us via phone.
-
Where to buy FLUKE 17B+ Digital Multimeter in Bangladesh?
You can buy FLUKE 17B+ Digital Multimeter online by ordering on BDTronics.com or directly collect by visiting our store in person. BDTronics is a trusted provider of high-quality electronics, 3D printers, solar systems, and robotics parts. We offer fast shipping across the country via courier service.
-
What are the delivery options of FLUKE 17B+ Digital Multimeter in Bangladesh?
We provide home delivery service all over Bangladesh. We support cash on delivery, bKash and Credit Card (Visa/ MasterCard/ Amex) payment solutions. The delivery time usually takes 1-2 days inside Dhaka and 2-3 days outside Dhaka.